Imprimir página
Disponível para encomenda
Tempo de Espera Habitual do Fabricante 8 Semana(s)
| Quantidade | Preço |
|---|---|
| 1+ | $ 1,144.340 |
| 5+ | $ 1,055.490 |
Unidades por pacoteEach
Mínimo: 1
Vários: 1
$ 1,144.34
Observação da linha
Adicionado a sua Confirmação de Pedido, Fatura, e Nota de envio apenas para esse pedido.
Informação do produto
FabricanteLEM
Nº da peça do fabricanteIN 400-SCópia
Prazo de entrega padrão do fabricante8 semanas
Código Newark25AK0782
Gama de produtosIN Series
Também conhecido por90.N6.48.000.0
Ficha técnica
Sensor Output TypeCurrent
Supply Voltage Range± 15V
Supply Voltage Range± 15V
Measured CurrentAC / DC
Accuracy0.001%
Current Sensor TechnologyClosed Loop Flux Gate
Primary Current400A
Secondary Signal Type266.7mA
Sensor MountingPanel Mount
Operating Temperature Min-40°C
Operating Temperature Max85°C
Product RangeIN Series
SVHCNo SVHC (25-Jun-2025)
Descrição geral do produto
IN 400-S is a current transducer used for electronic measurement of current: DC, AC, pulsed with galvanic separation between the primary and the secondary circuit. It is used as a feedback element in high performance gradient amplifiers for MRI and power supplies, calibration unit, energy measurement and medical equipment. For the Complies with EMC (EN 61000-6-2: 2016, EN 61000-6-3: 2007 + A1 (2011)), safety (EN 61010-1: 2010 + A1 (2016), IEC 61010-2-030: 2017) standards. Applications include industrial, laboratory and medical applications.
- Closed loop (compensated) current transducer using an extremely accurate zero flux detector
- Fluxgate technology reinvented (LEM patent), IPN = 400A
- 9 pin D-sub male secondary connector, flat or vertical panel mounting
- Status signal to indicate the transducer state, LED indicator confirms normal operation
- Metal housing to improve immunity to EMC & power dissipation
- Very high accuracy, excellent linearity, extremely low temperature drift, no insertion losses
- Wide frequency bandwidth, high immunity to external fields, very low noise on output signal
- Low noise feedback to primary conductor
- Operating temperature range from -40°C to 85°C
- Flat or vertical panel mounting
Especificações Técnicas
Sensor Output Type
Current
Supply Voltage Range
± 15V
Accuracy
0.001%
Primary Current
400A
Sensor Mounting
Panel Mount
Operating Temperature Max
85°C
SVHC
No SVHC (25-Jun-2025)
Supply Voltage Range
± 15V
Measured Current
AC / DC
Current Sensor Technology
Closed Loop Flux Gate
Secondary Signal Type
266.7mA
Operating Temperature Min
-40°C
Product Range
IN Series
Documentação técnica (4)
Legislação e Ambiente
US ECCN:EAR99
EU ECCN:Unknown
Conformidade RoHS:Sim
RoHS
Ftalatos compatíveis com RoHS:Sim
RoHS
SVHC (substâncias que suscitam elevada preocupação):No SVHC (25-Jun-2025)
Baixar o certificado de conformidade do produto
Certificado de conformidade do produto