HONEYWELL S&C  24PCEFA6G  Pressure Sensor, Miniature, Silicon, 0.5 psi, Differential, Gauge, Straight, Voltage, 12 VDC, 2 mA

HONEYWELL S&C 24PCEFA6G

Image is for illustrative purposes only. Please refer to product description.

  • Manufacturer:
  • Newark Part No.: 39B7043
  • Manufacturer Part No 24PCEFA6G

Product Specifications, Documents & More


  • External Depth: 16mm
  • Hysteresis: 0.15%
  • Operating Pressure Max: 0.5psi
  • Operating Pressure Min: 0psi
  • Operating Pressure Range: 0psi to 0.5psi
  • Port Style: Straight
  • Pressure Measurement Type: Differential, Gauge
  • SVHC: To Be Advised
  • Sensor Output: Voltage
  • Supply Current: 2mA
  • Voltage Rating: 12VDC

Find similar products  grouped by common attribute

This product also features on the following pages and catalog editions:

  •  /

Availability

Availability:  64


  • 64 in stock for same day shipping
 
Check stock and lead times
    More stock available week commencing 3/28/16

Price for: Each 1

Minimum order quantity: 1

Order multiple quantity: 1

Price: $28.23 $28.23

Buy

Price

Quantity List Price
1 - 9 $28.23
10 - 49 $22.45
50 - 99 $20.11
100 - 249 $19.42
250 - 499 $18.46
500 - 999 $17.77
1000+ $17.22
 
 
Low

Legislation and Environmental


Back to top

Similar Products


Find products functionally similar to this one. Select one of the following links, and you will be taken to a product group page that presents all products in this category that share the given attribute.

Back to top

Customer Reviews


HONEYWELL S&C - 24PCEFA6G - PRESSURE SENSOR, -0.5 to +0.5 PSI, STRAIGHT 5 5 1 1
Linearity and Common Mode Pressure Fluctuation Love these sensors, both 24 and 26 series. I use water or ethylene glycol in both ports. They give straight-line calibrations with r-squared of 0.9999 new and 0.999999 after a year. (The square fluorosilicon seal relaxes.) A calibration parabolic in both temperature and pressure with a PT term give at least two more 9's and 0.01% accuracy. Kind of amazing in a $20 sensor. With low-range silicon-strain-gage pressure sensors, the user needs to be aware that a pressure change common to both ports (such as barometric) causes a change in output voltage, owing to a volumetric strain on the sensor. Applying a full-scale-pressure input to both ports will cause an output change of 0.5 to 1% of full scale. Trivial in 30-PSI sensors; not trivial in 0.5-PSI sensors. December 8, 2012
  • 2015-06-11T15:22:19.459-05:00
  • bvseo_lps, prod_bvrr, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasreviews, tv_1, tr_1
  • loc_en_US, sid_39B7043, prod, sort_default
1-1 of 1
Back to top

Customer Q&A Exchange


Community


Like to see information about this product from other customers?

 Read discussions, blogs, documents from our community members.

Filters:

Post a question to one of our experts or start a discussion and get responses from supplier experts and fellow engineers in our community.
Back to top

Customers Also Bought