ManufacturerLEM
Manufacturer Part NoDVL 500
Newark Part No.99Y7932
Product RangeDVL Series
Technical Datasheet
Transducer FunctionVoltage Transformer
Supply Voltage Min-13.5V
Measured VoltageAC, DC, Pulsed
Supply Voltage Range± 13.5V to ± 26.4V
Supply Voltage Max26.4V
Supply Voltage Range± 13.5V to ± 26.4V
Primary Voltage Nom500V
Accuracy0.5%
Accuracy± 1%
Secondary Signal Type50mA
Input Current-mA
Sensor Output TypeAnalog
External Depth100mm
Sensor MountingPanel Mount
Output Current Max75mA
Operating Temperature Min-40°C
Output Current Max75mA
Operating Temperature Max85°C
Linearity %0.5%
Product RangeDVL Series
SVHCNo SVHC (25-Jun-2025)
Product Overview
DVL 500 is a voltage transducer for the electronic measurement of voltage DC, AC, pulsed with galvanic isolation between the primary and secondary circuit. Typical applications include single or three phase inverter, propulsion and braking chopper, propulsion chopper, auxiliary converter, high power drives and substations.
- Bipolar and isolated measurement up to 750V
- Current output, input and output connections with M5 studs, compatible with AV 100 family
- Low consumption and low losses
- Compact design, excellent accuracy(offset, sensitivity, linearity)
- Good response time
- Low temperature drift
- High immunity to external interference
- Isolated plastic case material recognized according to UL94-V0
Technical Specifications
Transducer Function
Voltage Transformer
Measured Voltage
AC, DC, Pulsed
Supply Voltage Max
26.4V
Primary Voltage Nom
500V
Accuracy
± 1%
Input Current
-mA
External Depth
100mm
Output Current Max
75mA
Output Current Max
75mA
Linearity %
0.5%
SVHC
No SVHC (25-Jun-2025)
Supply Voltage Min
-13.5V
Supply Voltage Range
± 13.5V to ± 26.4V
Supply Voltage Range
± 13.5V to ± 26.4V
Accuracy
0.5%
Secondary Signal Type
50mA
Sensor Output Type
Analog
Sensor Mounting
Panel Mount
Operating Temperature Min
-40°C
Operating Temperature Max
85°C
Product Range